CORE is a CloudEngine S8700-10 chassis: two slots (9 and 10) for SRU main control boards, which hold the control plane and the switch fabric, and eight slots for line cards (LPUs), which hold the ports. It arrives with power, fans and one 48 x 10GE line card in slot 1, already cabled to the access switches — but no SRU, so it cannot start. Build it, then make it the gateway for VLANs 10 and 20.
The simulator ticks each one as soon as the network meets it.
Insert the main control board: hardware insert slot 9 LSG7SRUFX1T0 (or use MODULES in the Device panel). The switch starts, and display device shows slot 9 as Master and slot 1 as Registered.
Insert a second SRU in slot 10: display device lists it as the Slave (standby) board.
Add a 48 x GE line card (LSG7G48TX1E0) in slot 2 for future access ports: its interfaces appear as GE2/0/1 to GE2/0/48.
On CORE, create VLANs 10 and 20, make 10GE1/0/1 and 10GE1/0/2 trunks carrying them, and give Vlanif10 192.168.10.1/24 and Vlanif20 192.168.20.1/24. PC1 pings PC2.
Run slave switchover: slot 10 becomes the master, and PC1 still reaches PC2.