Objectives
The simulator ticks each one as soon as the network meets it.
VLAN 20 is outside the VLAN pool: extend POOL1 so it holds VLAN 20.
AEP1 is not attached to the physical domain: attach PHYS1.
Port 1/3 of leaf 102 has no policy group: give it HOSTS.
show faults is empty, and PC1 reaches PC2 (192.168.10.20).
Before you start
Read each fault as one link: EPG to domain, domain to pool, port to AEP, AEP to domain. A fault names only the first break on a path, so a new one can appear after you fix one.
Concept
ACI: the physical domain chain
A VLAN works on a port only if a chain of policies allows it. The EPG names a physical domain, the domain names a VLAN pool that holds the VLAN, and the port’s policy group names an AEP attached to that domain. A break anywhere raises a fault that names it. A classic switch joins through this chain, on a port or a vPC.
Concept
Physical domains: joining classic switches to a fabric
Most fabrics must reach racks that know nothing about VXLAN: classic switches and bare-metal servers on tagged VLANs. The fabric treats that network as a physical domain. A leaf pair presents one LACP partner, carries the tagged VLANs on a trunk, and maps each VLAN to a VNI, so a host on a classic switch reaches a host anywhere in the fabric. Only VLANs that are mapped cross, and each stays separate.