Objectives
The simulator ticks each one as soon as the network meets it.
On CORE, read display alarm active while the faults are there: it names the powered-off board in slot 1.
Power the line card back on (power on slot 1).
10GE1/0/2 is still down. Read display logbuffer on ACC2 to see which of its interfaces went down, and bring that uplink back up. PC1 pings PC2.
display alarm active on CORE now reports no active alarm; check display health, display cpu-usage and display memory-usage too.
Rate this lab
No ratings yet.
Sign in to rate this lab and keep track of the labs you finish.
Before you start
display alarm active lists what is wrong right now; display logbuffer and display trapbuffer record what happened, newest first. A port that is down because its peer is shut shows no shutdown in its own configuration: look at the other end. display health puts temperature, power, CPU, memory and flash in one screen.
Concept
Device health: alarms, logs, CPU and memory
A network device reports on itself. Alarms say what is wrong now; the log and trap buffers record what happened and when; CPU, memory, temperature and power readings show whether the device itself is struggling. Reading them first turns "nothing works" into a short list of facts.
Concept
Modular switches: control, fabric and line cards
A modular switch is a chassis with slots. Main control boards run the control plane (the CLI, routing protocols, the configuration); the switch fabric moves packets between slots; line cards hold the ports and forward packets. On the CloudEngine S8700 the fabric is built into the SRU main control boards, so there are no separate fabric boards.